Why is there a heart rate after the person leaves?
A proposed departure-and-return test of held rates, explicit zeros and missing reports. Compare what the radar sends with what a display keeps showing.
Device profile · Seeed Studio MR60BHA2 Breathing and Heartbeat Kit ↗Mark the transitions
Record the radar firmware, XIAO application or ESPHome version, mounting angle and room conditions. Use one volunteer and a fixed radar. First establish a still baseline while lying in Seeed’s recommended sleep installation. In a separate controlled departure, mark when the participant rises, moves beyond 1.5 m and leaves, then returns. The movement is a state-transition test, not a valid rate measurement. Timestamp each transition on the same clock as the logger. Repeat with the room empty between trials. Reporting conditions
Give each field its own clock
For each rate record the latest report arrival and the time its number last changed. Add a timestamped presence event from the UART presence message (type 0x0F09) if you need an explicit empty-room state. The Arduino 1.0.0 presence getter can return false when no new presence frame was read. Log a real zero, an explicit clear, and no update as separate events. Arduino receive logic · Start with the USB logger
Compare with Home Assistant
In a separate run with ESPHome, keep has_target configured as in Seeed’s example. In ESPHome 2026.10.2 the parser skips an all-zero individual rate payload. An explicit no-target report can instead set both configured rates to zero. The component has no per-rate silence timer. Disconnect and reconnect the network during an empty interval, starting the new connection in an unknown state. Record what the dashboard actually does. ESPHome 2026.10.2 parser · Seeed’s YAML
Decide what to display
Measure time from marked departure to the last displayed number, time to an explicit clear or an application timeout, and time from return to the first eligible report. Mark trials with no such event as unresolved. Choose a timeout from observed cadence before comparing later runs. Show historical or unknown when occupancy, range or report age cannot support a current reading. No trials have been run.