Inside AI
← Ideas Lab
Experiment · unrun / Experimental/DIY Hardware

Map radar interference and the limits of static presence

A proposed room test of mounting, bedding, fans and curtains. Use the 4 m and 6 m marks for static presence and the close zone for vital-rate availability.

Device profile · Seeed Studio MR60BHA2 Breathing and Heartbeat Kit ↗

Establish two separate baselines

Record radar firmware, placement, mounting angle, room layout and which fields the logger receives. With a fixed mount, test static presence at marked distances including 4 m and 6 m. For rates use one still person in the 0.5–1.5 m core zone. Record empty-room control intervals of the same duration. Versioned limits · Store’s empty-environment figure

Vary one condition at a time

Keeping positions fixed, compare fan off/on and curtains still/moving in an empty room. In separate occupied runs compare mounting angle, posture and bedding. Note any vibration of the support. An observer’s marked occupancy and distance supply the reference. A nonzero heart rate with zero breathing is an event to record.

Report by condition

Report false occupied seconds divided by observed empty seconds, missed occupied seconds divided by occupied seconds, and time until eligible reports return. Split out missing reports and never infer separate rates for two people. These trials address reliability in this room and firmware. They do not establish clinical accuracy.

Primary sources

Seeed’s MR60BHA2 kit setup Seeed MR60BHA2 kit and warehouse prices Seeed’s MR60BHA2 reporting rules and Home Assistant guide