Inside AI
← Build & Hack
Proposed build / Experimental/DIY Hardware

Log your first MR60BHA2 radar reports over USB

Flash Seeed’s Arduino example, read its three labeled fields, then save a local CSV that keeps arrival time separate from value changes. This build is proposed.

Device profile · Seeed Studio MR60BHA2 Breathing and Heartbeat Kit ↗
Start with the documented setup

This is a proposed workflow. Follow the linked official setup, then use the checks below to decide whether it works on your hardware.

MR60BHA2 kit outside its enclosure, with the antenna patches at one end of the radar board and a USB-C connector on the carrier.
Official photo associated with SKU 114993387. It shows the module assembly, not a teardown of the shielded radar chip. Copyright Seeed Studio; separate reuse permission unverified. Hardware reference for this proposed build; not a result from our test. Seeed Studio ↗

Get one reading

Use SKU 114993387, a computer, a USB-C data cable and a stable support. Install the ESP32 board package and Seeed Arduino mmWave library, select XIAO ESP32C6 and upload mmwaveBreath. This replaces the preloaded ESPHome application on the XIAO. Open the serial monitor at 115200 baud and follow Seeed’s sleep installation: mount securely about 1 m above the head of the bed, angle about 45° toward the middle, and keep one consenting still participant’s chest within 1.5 m. Do not use a seated desk or exercise session to judge rate output. Look for separate heart_rate, breath_rate and distance lines. A silent console calls for a cable and port check. Keep any missing field marked missing. Getting started · Official sketch · Restore ESPHome

Save the arrivals

Close the serial monitor so the port is free. On your computer, install pyserial, save this example as radar_log.py and run python radar_log.py COM3 > run.csv, substituting your port (for example /dev/ttyACM0 on Linux). Stop with Ctrl+C. Each row is one labeled report printed by the example. Phase lines are skipped. The timestamps count seconds from opening the port. Start a new file after reconnecting.

import csv
import re
import sys
import time

import serial  # Install with python -m pip install pyserial

field = re.compile(rb"(heart_rate|breath_rate|distance): (-?\d+\.\d+)")
last = {}
out = csv.writer(sys.stdout)
out.writerow(["arrival_s", "field", "value", "previous_arrival_s",
              "last_value_change_s"])
with serial.Serial(sys.argv[1], 115200, timeout=1) as port:
    start = time.monotonic()
    try:
        while True:
            match = field.fullmatch(port.readline().strip())
            if match is None:
                continue
            t = round(time.monotonic() - start, 3)
            key = match[1].decode("ascii")
            value = float(match[2])
            old, prev, changed = last.get(key, (None, "", t))
            if value != old:
                changed = t
            last[key] = (value, t, changed)
            out.writerow([t, key, value, prev, changed])
            sys.stdout.flush()
    except KeyboardInterrupt:
        pass

Read two different clocks

Two rows with the same heart rate can have different arrival times and the same last-change time. A gap between arrivals tells you how long the host went without that type of report. It does not date the radar’s underlying estimate. The official rate sketch does not print explicit presence frames. Add those separately for the departure experiment. Rate frame payloads · Mark departures and missed reports

What it costs

With computer, cable and support already on hand, the first-year incremental Seeed subtotal is US$24.21 from China or Germany, or US$25.19 from the US, checked 18 Nov 2026. Add missing equipment at its actual price. The local logger needs no paid plan or Home Assistant host. Tax, shipping, duties, electricity and labor are excluded. Adjust the budget

Primary sources

Seeed’s MR60BHA2 kit setup Seeed’s MR60BHA2 reporting rules and Home Assistant guide Seeed mmwaveBreath starter sketch Seeed Arduino MR60BHA2 parser, version 1.0.0