Inside AI
← Ideas Lab
Experiment · unrun / Edge AI

How quickly does the indicator clear?

Proposed experiment · Test whether a departed participant leaves a stale presence signal.

Device profile · Raspberry Pi AI Camera ↗

Procedure

Mark a standing position and lock the mount and focus. Use the same model, detection threshold and three-result rule throughout. Run ten entry/exit cycles, alternating upright and seated postures. A second observer records actual presence and state changes against one clock. Avoid recording video or identifying details.

Readout

Report missed entries, false ‘no pose’ intervals during occupancy, false ‘pose present’ intervals after exit, and time from exit to the first stable ‘no pose’ state. List unknown intervals separately. Include successful-trial counts with delay statistics so a rapid successful subset cannot conceal failures.

What would falsify the design?

Define an acceptance window before the first run. For example, require nine of ten exits to clear within two seconds. A single missed clearing past the observation period remains a miss. Repeat under different framing before interpreting a result as portable.

Evidence status

Unrun. The manufacturer example documents host decoding and cached display results; this experiment proposes a different state policy and has no measured hardware results. HigherHRNet Python example

Primary sources

HigherHRNet Python example