Will UnitV2 labels stay useful on a real bench?
An unrun plan to compare lighting, occlusion, false triggers and UART freshness before using a recognition result for control.
Device profile · M5Stack UnitV2 AI Camera (U078-D) ↗Establish the factory baseline
Record U078-D firmware, function/model name, lens distance, browser and host. Run the unchanged Object Recognition example with one supported bottle or cup on a clear bench. Observe preview and UART JSON if a controller is available. Do not mix a custom model into the first baseline.
Vary one condition at a time
Proposed matrix: bright/low light, plain/cluttered background, partial occlusion and object absent. For each condition, log intended class, reported class, confidence, box and the interval from scene change to fresh result. Compare false positives and missing detections; distinguish a stale last frame from a new detection. Values and thresholds should be chosen for the application before testing; none are vendor guarantees.
Probe the application boundary
If a separate UART controller is used, compare device preview events with received JSON IDs/timestamps and test unplug/reconnect. Confirm whether output persists, resets or repeats after disconnection. Try the optional V-Training path only after documenting account terms and uploaded-image privacy.
Decision consequence
A stable, fresh result can support a reversible desk indicator. Repeated false triggers or stale outputs favor manual confirmation, a different camera/lighting setup or a richer vision platform. No measurements or hardware tests have been performed by Inside AI.