Inside AI
← Ideas Lab
Experiment · unrun / Edge AI

Can a local vision event survive a real desk?

Unrun test plan · Test occlusion, stale frames, network loss and the cost of leaving the dashboard open.

Device profile · Seeed Studio reCamera 2002 ↗

Scene protocol

Proposed first test: 30 removals and 30 replacements across three lighting conditions, plus 30 hand occlusions without removal. Keep test sessions separate from training and threshold tuning. Record missed transitions, false removals, unknown time and total scene-change-to-event delay.

System protocol

Repeat with dashboard open and closed, then interrupt the receiver and restart the camera. Disconnect internet access while keeping the local network. Check that the installed model still works, stale input becomes unknown and reconnection reconciles state. Observe a one-hour run for crashes or growing delay.

Proposed acceptance gates

For this limited prototype, target no false removal from the 30 hand occlusions, at least 95% correct removal/replacement events, and no silent stale state after a camera error. These are chosen goals, not measured results or suitability guarantees. Report median and 95th-percentile latency and all failures, including those excluded from timing.

Open questions

Model/domain accuracy, quantization effects, recovery behavior, memory pressure with the chosen flow and long-run stability. No tests have been run on physical hardware.

Primary sources

Seeed reCamera hardware matrix and design resources reCamera 2002 quick start and variant guide reCamera online model conversion and supported tasks reCamera 2002 64 GB official listing