Inside AI
← Deep Dives
Deep dive / Edge AI

From a detection box to one useful event

Architecture study · The model detects; your application decides whether something actually changed.

Device profile · Seeed Studio reCamera 2002 ↗

Capture and compute

The standard sensor, core and base are replaceable hardware modules. Pixels are processed on the device and a compatible model executes using its inference stack. This is a camera-plus-compute appliance, unlike a Pi camera that depends on a separate Pi host. Hardware reference

Model output is not application state

A detector returns class scores and boxes for a frame. In our proposed flow, a tray region excludes nearby clutter; a persistence rule avoids flickering state changes. A confidence threshold does not make missed detections impossible, and temporary occlusion should not be mistaken for removal.

Define a state transition

Proposed states: present, absent and unknown. Require a validated interval of usable observations before changing present ↔ absent. A camera error or a stale frame produces unknown. Include a sequence number in each emitted transition so a receiver can detect gaps or duplicates.

Separate development from deployment

The documented online path converts fixed-shape ONNX detection models into .cvimodel using Seeed’s cloud service. It is a build-stage dependency; the deployed artifact can be used offline. Test the exact OS and model pair before describing an application as offline. Conversion documentation

Resolve documentation conflicts

A generic conversion article describes different CV181x specifications. For this profile, the 2002-specific hardware matrix, standard product listing and quick-start define the SKU; the online converter guide defines its supported model path. Do not copy a generic tutorial’s RAM, sensor or TOPS values into a product specification.

Evidence boundary

The component roles and available software route are manufacturer-documented. The region filter, state machine and receiver protocol are our proposed design; no reCamera has been configured or measured by this lab.

Primary sources

Seeed reCamera hardware matrix and design resources reCamera 2002 quick start and variant guide reCamera online model conversion and supported tasks reCamera 2002 64 GB official listing