Does it recognize a wave from someone new?

Proposed experiment · Count missed actions, duplicate alerts and background activations on unseen wearers.

Device profile · Arduino Nano 33 BLE Sense Rev2 ↗

Reserve people, not windows

Before fitting the model, reserve at least two people who provide no training or tuning recordings. Collect separate sessions on different occasions, remounting the board each time. Freeze the model, class order, sample rate, firmware, thresholds and decision interval before opening the test set. Training and trigger rule

Script the positives and negatives

Per held-out wearer, ask for 10 separated bouts of waving at a comfortable pace. Then collect at least five uninterrupted minutes of normal carrying, resting, reaching and strap adjustment with no requested wave. Record the onset and end of each requested bout and the timestamps of all serial events, using a shared clock. State the mounting position and hand used.

Score events with an explicit time rule

Before the run, fix the acceptance interval (for example, cue onset through one second after the bout ends). Match at most one event to each bout. Record missed bouts, duplicate events inside a matched interval and cue-to-first-event delay. For background-only trials divide unexpected events by observed background minutes; include counts and minutes beside the rate. Report per wearer as well as pooled.

Interpret the failure

If within-person validation looks strong but a held-out wearer misses most cues, inspect orientation and the gesture definition before changing the thresholds. If carrying produces repeated alerts, add those negative motions to the next training round and reserve fresh people for its final test. No accuracy, latency or false-trigger rate has yet been measured. Why mounting changes the signal